{"product_id":"450kw-scr-power-regulator-panel-3-phase-380v","title":"450kW 3 Phase SCR Power Controller | Industrial Grade Thyristor Heater Control System","description":"\u003ctable style=\"width:100%; font-size: 12px;\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel NO.\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAPR3H450G\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNew\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eCustomized\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e3\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e380V +\/-15%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAdaptive\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eResistive Load\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eOther Voltage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e220V, 440V, 690V, 1140V, Custom\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e50\/60Hz\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSCR Power Controller\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduction Capacity\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e500,000 pcs\/year\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eKeypad\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eExternal Keyboard Available\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Mode\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePhase-Angle, Zero-Crossing\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003ePackage\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCarton Box, Pallet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e270 * 390 * 460 mm\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eTrademark\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAIGOODELE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eChina\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e9032899099\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003eOur SCR Power Controller offers precise power and temperature regulation, making it ideal for various industrial applications. Designed with flexibility and reliability in mind, it supports multiple control modes:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eConstant power control\u003c\/li\u003e \u003cli\u003eConstant current control\u003c\/li\u003e \u003cli\u003eOpen loop control\u003c\/li\u003e \u003cli\u003eCycle zero crossing control\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eTo ensure safe and efficient operation, the controller includes the following protective features:\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePower supply phase loss protection\u003c\/li\u003e \u003cli\u003eRadiator overheat protection\u003c\/li\u003e \u003cli\u003eLoad overcurrent protection\u003c\/li\u003e \u003cli\u003eThree-phase current unbalance protection\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe device is equipped with an LCD display for real-time monitoring, allowing easy customization of parameters. Input methods such as \u003cstrong\u003e4-20mA\u003c\/strong\u003e, \u003cstrong\u003e0-5V\u003c\/strong\u003e, \u003cstrong\u003e0-10V\u003c\/strong\u003e, and \u003cstrong\u003epotentiometer\u003c\/strong\u003e control are supported, ensuring seamless integration with PLCs and other systems.\u003c\/p\u003e \u003cp\u003eFor effective heat management, each unit comes with dual DC fans and radiators, guaranteeing optimal performance and extending the lifespan of the controller. The energy-saving constant temperature control reduces power fluctuations and enhances operational efficiency.\u003c\/p\u003e \u003cp\u003eFor loads like silicon carbon rods or heaters, this controller provides excellent performance, ensuring safety and efficiency in your operations. The operation panel can also be extended with a lead-out cable for easy integration into your specific setup.\u003c\/p\u003e \u003cp\u003eFor customization options or further assistance, feel free to contact our customer support team.\u003c\/p\u003e \u003ch3\u003eTerminal Functions\u003c\/h3\u003e \u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0616\/4889\/6044\/files\/3_scr_power_controller_terminal_functions.jpg?v=1734768715\"\u003e\u003c\/p\u003e \u003ctable style=\"max-width: 800px; margin: 0 auto 24px auto;\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eNo.\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eMark\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eFunctional Description\u003c\/b\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e1\u003c\/td\u003e \u003ctd\u003eP+\u003c\/td\u003e \u003ctd\u003eReference power supply +5V: Feed reference for external potentiometers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e2\u003c\/td\u003e \u003ctd\u003eAI1\u003c\/td\u003e \u003ctd\u003eCurrent analog input port1: DC0~20420mA (input impedance 1252), with 4-terminal GND to form an input loop.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e3\u003c\/td\u003e \u003ctd\u003eAI2\u003c\/td\u003e \u003ctd\u003eVoltage analog input port 2: 0~5V input\/potentiometer input (center tap)\/DC0~10V, and GND form the input circuit. 0~5V 0~10V no need to connect P+\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e4\u003c\/td\u003e \u003ctd\u003eGND\u003c\/td\u003e \u003ctd\u003eSignal common ground: analog signal negative terminal, switch signal common terminal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e5\u003c\/td\u003e \u003ctd\u003ePWM\u003c\/td\u003e \u003ctd\u003eSignal Analog, PWM Input Port\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e6\u003c\/td\u003e \u003ctd\u003e4-20mA Output\u003c\/td\u003e \u003ctd\u003e4-20mA output+\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e7\u003c\/td\u003e \u003ctd\u003eCOM\u003c\/td\u003e \u003ctd\u003e4-20mA output-\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e8\u003c\/td\u003e \u003ctd\u003eA\u003c\/td\u003e \u003ctd\u003eRS485 communication port, RS485+\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e9\u003c\/td\u003e \u003ctd\u003eB\u003c\/td\u003e \u003ctd\u003eRS485 communication port, RS485-\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10\u003c\/td\u003e \u003ctd\u003eSW1\u003c\/td\u003e \u003ctd\u003eExternal start\/stop control terminal: SW1 and 12 terminal GND constitute the start\/stop, when the two terminals are closed, the adjuster work\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e11\u003c\/td\u003e \u003ctd\u003eSW2\u003c\/td\u003e \u003ctd\u003eAnalog input port selection: SW2 and terminal 12 GND, closed to select analog input port 2; disconnected to select the input port\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e12\u003c\/td\u003e \u003ctd\u003eGND\u003c\/td\u003e \u003ctd\u003eSignal common ground: analog signal negative terminal, switch signal common terminal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e13\u003c\/td\u003e \u003ctd\u003eNO\u003c\/td\u003e \u003ctd colspan=\"1\" rowspan=\"3\"\u003eOutput relay 1: according to the menu A basic parameters A07 function selection can be used as an output signal, or fault alarm output signal No., load capacity AC240V\/5A, DC24V\/5A NO: Normally open NC: Normally closed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e14\u003c\/td\u003e \u003ctd\u003eCOM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e15\u003c\/td\u003e \u003ctd\u003eNC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e16\u003c\/td\u003e \u003ctd\u003eNO\u003c\/td\u003e \u003ctd colspan=\"1\" rowspan=\"3\"\u003eOutput relay 2: according to the menu A basic parameters A08 function selection can be used as an output signal, or fault alarm output signal No., load capacity AC240V\/5A, DC24V\/5A NO: Normally open NC: Normally closed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e17\u003c\/td\u003e \u003ctd\u003eCOM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e18\u003c\/td\u003e \u003ctd\u003eNC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e20\u003c\/td\u003e \u003ctd\u003eL\u003c\/td\u003e \u003ctd colspan=\"1\" rowspan=\"2\"\u003eExternal AC 220V power supply\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e21\u003c\/td\u003e \u003ctd\u003eN\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eWiring Diagram\u003c\/h3\u003e \u003cp\u003eHere’s how you can connect our SCR power controllers based on different control signals. Each control method is designed for ease of use and ensures efficient and safe power regulation for your heating systems:\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cb\u003eControl Signal: 4-20mA\u003c\/b\u003e\u003cbr\u003eThis is one of the most common methods for regulating heating power. For detailed instructions on how to connect the SCR power controllers with a 4-20mA temperature controller, please refer to our .\u003c\/li\u003e \u003cli\u003e \u003cb\u003eControl Signal: 0-5V \/ 0-10V\u003c\/b\u003e\u003cbr\u003eIf you are using a DC voltage signal (0-5V or 0-10V) to control heating power, our controllers support this input. For the wiring details, check our .\u003c\/li\u003e \u003cli\u003e \u003cb\u003eControl Signal: Potentiometer\u003c\/b\u003e\u003cbr\u003eA potentiometer can also be used to adjust the heating power. Learn how to wire the SCR power controllers with a potentiometer as an input signal in our .\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0616\/4889\/6044\/files\/wirings_with_different_control_signals.jpg?v=1735112946\"\u003e\u003c\/p\u003e \u003ch3\u003eHuman-Machine Interface\u003c\/h3\u003e \u003cp\u003eAIGOODELE SCR power controllers feature a user-friendly HMI with a clear LCD display that allows easy monitoring of real-time status and quick adjustments. Parameters such as control modes, output power, and protection settings can be configured directly from the display. Designed for simplicity, the interface provides precise control over heating applications, making it easy to operate. For more details, check out our .\u003c\/p\u003e \u003cp\u003e\u003ciframe width=\"369\" height=\"640\" src=\"https:\/\/www.youtube.com\/embed\/Y5ZfgmRVn8A?si=1yB3vB_lV6PJDoau\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e \u003ch3\u003eQuick Selection\u003c\/h3\u003e \u003cp\u003eThe following table provides a quick reference to select the appropriate SCR power controller based on your heater's voltage and power requirements. For a detailed guide on selecting the right SCR power controller, please visit our .\u003c\/p\u003e \u003ctable style=\"margin-top: 12px;\"\u003e \u003cthead\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003e220V Heater Power (kW)\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003e380V Heater Power (kW)\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003e440V Heater Power (kW)\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e\u003cb\u003eSCR Power Controller Selection\u003c\/b\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e0 \u0026lt; P ≤ 7.41\u003c\/td\u003e \u003ctd\u003e0 \u0026lt; P ≤ 12.8\u003c\/td\u003e \u003ctd\u003e0 \u0026lt; P ≤ 14.82\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e7.41 \u0026lt; P ≤ 10.19\u003c\/td\u003e \u003ctd\u003e12.8 \u0026lt; P ≤ 17.6\u003c\/td\u003e \u003ctd\u003e14.82 \u0026lt; P ≤ 20.38\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10.19 \u0026lt; P ≤ 13.89\u003c\/td\u003e \u003ctd\u003e17.6 \u0026lt; P ≤ 24\u003c\/td\u003e \u003ctd\u003e20.38 \u0026lt; P ≤ 27.79\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e13.89 \u0026lt; P ≤ 18.53\u003c\/td\u003e \u003ctd\u003e24 \u0026lt; P ≤ 32\u003c\/td\u003e \u003ctd\u003e27.79 \u0026lt; P ≤ 37.05\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e18.53 \u0026lt; P ≤ 23.16\u003c\/td\u003e \u003ctd\u003e32 \u0026lt; P ≤ 40\u003c\/td\u003e \u003ctd\u003e37.05 \u0026lt; P ≤ 46.32\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e23.16 \u0026lt; P ≤ 27.79\u003c\/td\u003e \u003ctd\u003e40 \u0026lt; P ≤ 48\u003c\/td\u003e \u003ctd\u003e46.32 \u0026lt; P ≤ 55.58\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e27.79 \u0026lt; P ≤ 32.42\u003c\/td\u003e \u003ctd\u003e48 \u0026lt; P ≤ 56\u003c\/td\u003e \u003ctd\u003e55.58 \u0026lt; P ≤ 64.84\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e32.42 \u0026lt; P ≤ 37.05\u003c\/td\u003e \u003ctd\u003e56 \u0026lt; P ≤ 64\u003c\/td\u003e \u003ctd\u003e64.84 \u0026lt; P ≤ 74.11\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e37.05 \u0026lt; P ≤ 41.68\u003c\/td\u003e \u003ctd\u003e64 \u0026lt; P ≤ 72\u003c\/td\u003e \u003ctd\u003e74.11 \u0026lt; P ≤ 83.37\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e41.68 \u0026lt; P ≤ 46.32\u003c\/td\u003e \u003ctd\u003e72 \u0026lt; P ≤ 80\u003c\/td\u003e \u003ctd\u003e83.37 \u0026lt; P ≤ 92.63\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e46.32 \u0026lt; P ≤ 50.95\u003c\/td\u003e \u003ctd\u003e80 \u0026lt; P ≤ 88\u003c\/td\u003e \u003ctd\u003e92.63 \u0026lt; P ≤ 101.89\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e50.95 \u0026lt; P ≤ 61.14\u003c\/td\u003e \u003ctd\u003e88 \u0026lt; P ≤ 105.6\u003c\/td\u003e \u003ctd\u003e101.89 \u0026lt; P ≤ 122.27\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e61.14 \u0026lt; P ≤ 69.47\u003c\/td\u003e \u003ctd\u003e105.6 \u0026lt; P ≤ 120\u003c\/td\u003e \u003ctd\u003e122.27 \u0026lt; P ≤ 138.95\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e69.47 \u0026lt; P ≤ 74.11\u003c\/td\u003e \u003ctd\u003e120 \u0026lt; P ≤ 128\u003c\/td\u003e \u003ctd\u003e138.95 \u0026lt; P ≤ 148.21\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e74.11 \u0026lt; P ≤ 81.05\u003c\/td\u003e \u003ctd\u003e128 \u0026lt; P ≤ 140\u003c\/td\u003e \u003ctd\u003e148.21 \u0026lt; P ≤ 162.11\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e81.05 \u0026lt; P ≤ 92.63\u003c\/td\u003e \u003ctd\u003e140 \u0026lt; P ≤ 160\u003c\/td\u003e \u003ctd\u003e162.11 \u0026lt; P ≤ 185.26\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e92.63 \u0026lt; P ≤ 101.89\u003c\/td\u003e \u003ctd\u003e160 \u0026lt; P ≤ 176\u003c\/td\u003e \u003ctd\u003e185.26 \u0026lt; P ≤ 203.79\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e101.89 \u0026lt; P ≤ 115.79\u003c\/td\u003e \u003ctd\u003e176 \u0026lt; P ≤ 200\u003c\/td\u003e \u003ctd\u003e203.79 \u0026lt; P ≤ 231.58\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e115.79 \u0026lt; P ≤ 129.68\u003c\/td\u003e \u003ctd\u003e200 \u0026lt; P ≤ 224\u003c\/td\u003e \u003ctd\u003e231.58 \u0026lt; P ≤ 259.37\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e129.68 \u0026lt; P ≤ 138.95\u003c\/td\u003e \u003ctd\u003e224 \u0026lt; P ≤ 240\u003c\/td\u003e \u003ctd\u003e259.37 \u0026lt; P ≤ 277.89\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e138.95 \u0026lt; P ≤ 148.21\u003c\/td\u003e \u003ctd\u003e240 \u0026lt; P ≤ 256\u003c\/td\u003e \u003ctd\u003e277.89 \u0026lt; P ≤ 296.42\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e148.21 \u0026lt; P ≤ 162.11\u003c\/td\u003e \u003ctd\u003e256 \u0026lt; P ≤ 280\u003c\/td\u003e \u003ctd\u003e296.42 \u0026lt; P ≤ 324.21\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e162.11 \u0026lt; P ≤ 185.26\u003c\/td\u003e \u003ctd\u003e280 \u0026lt; P ≤ 320\u003c\/td\u003e \u003ctd\u003e324.21 \u0026lt; P ≤ 370.53\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e185.26 \u0026lt; P ≤ 208.42\u003c\/td\u003e \u003ctd\u003e320 \u0026lt; P ≤ 360\u003c\/td\u003e \u003ctd\u003e370.53 \u0026lt; P ≤ 416.84\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e208.42 \u0026lt; P ≤ 231.58\u003c\/td\u003e \u003ctd\u003e360 \u0026lt; P ≤ 400\u003c\/td\u003e \u003ctd\u003e416.84 \u0026lt; P ≤ 463.16\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e231.58 \u0026lt; P ≤ 254.74\u003c\/td\u003e \u003ctd\u003e400 \u0026lt; P ≤ 440\u003c\/td\u003e \u003ctd\u003e463.16 \u0026lt; P ≤ 509.47\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e254.74 \u0026lt; P ≤ 277.89\u003c\/td\u003e \u003ctd\u003e440 \u0026lt; P ≤ 480\u003c\/td\u003e \u003ctd\u003e509.47 \u0026lt; P ≤ 555.79\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e277.89 \u0026lt; P ≤ 291.79\u003c\/td\u003e \u003ctd\u003e480 \u0026lt; P ≤ 504\u003c\/td\u003e \u003ctd\u003e555.79 \u0026lt; P ≤ 583.58\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eDownload Manual\u003c\/h3\u003e \u003cp\u003e\u003c\/p\u003e","brand":"AIGOODELE","offers":[{"title":"Default Title","offer_id":46092621807789,"sku":"APR3H450G","price":2758.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0751\/8493\/0989\/files\/Sc312856b6f894302bcfe107e1ebba7feZ.webp?v=1780910305","url":"https:\/\/norlato.com\/products\/450kw-scr-power-regulator-panel-3-phase-380v","provider":"norlato","version":"1.0","type":"link"}